Browse By Repository:

 
 
 
   

Development of energy regenerative system from air conditioner waste

Salim, Nur Anis Suraya (2017) Development of energy regenerative system from air conditioner waste. Project Report. Universiti Teknikal Malaysia Melaka, Melaka, Malaysia. (Submitted)

[img] Text (24 Pages)
Development Of Energy Regenerative System From Air Conditioner Waste.pdf - Submitted Version

Download (1MB)
[img] Text (Full Text)
Development of energy regenerative system from air conditioner waste.pdf - Submitted Version
Restricted to Repository staff only

Download (10MB)

Abstract

Nowadays, the global energy consumption is increased rapidly especially in the developing countries. This is due to the high of the population and economic growth that lead to higher demands of the energy that only can make it in a critical situation. Thus, it has to be conserved in good ways so that these non-renewable energy sources would not be depleted in the future. The idea of using the renewable energy technology is steadily increased for the past few years in order to meet the requirement of the energy demands. The renewable energy has a very impressive potential of resources that is very useful in cost reduction of natural costs that connected to the customary energy supply system to make it as the option energy source, later on, to be used. Thus, the aim of this project is to develop the energy regenerative system from air conditioner waste. This can decrease the wasted air that been discharged freely to environment without further action. The wind turbine mechanism is been applied throughout this project. Hence the objective of this project is to design and develop a prototype of Waste Kinetic Energy Recovery System (WKERS) for generating the electricity from air conditioner condenser and also analyze the performance of the Waste Kinetic Energy Recovery System (WKERS) prototype with the experimental test. There are three types of blade that been used such as NREL, Swept and Elliptical. Then, the result of the performance for each blades is tabulated in the table and graph. As a conclusion, the average voltage output and turbine rotation (rpm) are affected by the distance of the wind turbine from the condenser.

Item Type: Final Year Project (Project Report)
Uncontrolled Keywords: Air conditioning, Renewable energy sources
Subjects: T Technology > T Technology (General)
T Technology > TJ Mechanical engineering and machinery
Divisions: Library > Final Year Project > FKP
Depositing User: Mohd Hannif Jamaludin
Date Deposited: 11 Jun 2018 01:03
Last Modified: 14 Dec 2023 03:11
URI: http://digitalcollection.utem.edu.my/id/eprint/21052

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year