This project will focus on power factor correction and harmonic filter circuit designed for electronic ballast fluorescent lamp. The selected electronic ballast fluorescent lamp with high harmonic and low power factor is improved by added the valley fill passive power factor correction circuit after the fully control bridge rectifier. Valley fill circuit is used because it is due to low cost, high efficiency and simple circuit design. The power factor can be increase 35%, current total harmonics distortion reduced 41.8% and voltage 25.6%. This valley fill passive power factor correction circuit is suitable for increasing the power factor and reducing the harmonic.