Effect of cold chamber parameter on the gas flow in thermal transpiration pump

Che Mohd Nasir, Nurul A’tiqah (2023) Effect of cold chamber parameter on the gas flow in thermal transpiration pump. Project Report. Universiti Teknikal Malaysia Melaka, Melaka, Malaysia. (Submitted)

[img] Text (24 Pages)
Effect of cold chamber parameter on the gas flow in thermal transpiration pump.pdf - Submitted Version

Download (622kB)
[img] Text (Full text)
Effect of cold chamber parameter on the gas flow in thermal transpiration pump.pdf - Submitted Version
Restricted to Registered users only until January 2028.

Download (1MB)

Abstract

This study of the effects of cold chamber parameter on gas flow in thermal transpiration pumps focuses on the installation of a cooling system to the cold chamber design. This is since a greater temperature in the hot chamber and a lower temperature in the cold chamber might result in a temperature gradient, a pressure difference, and gas flow in the Knudsen pump. As the goal of the cooling system is to help the cold chamber in maintaining a cold temperature without severe temperature increases from hot gas temperatures, the cooling system helps the cold chamber to maintain a cold temperature. TEC1-12706 Utilizing the cold side of the Peltier and a water-cooling system at the hot side of the Peltier, a Peltier is utilised in the cooling system to obtain cold temperatures. Zero changes in the hot chamber, the addition of rockwool, and the addition of both rockwool and wiremesh are investigated. The finding is made by analysing the temperature difference between two regions in which the characteristics of different types of hot chambers are analysed with and without a cooling system. The pressure of the example with the highest temperature gradient is observed to determine the existence of pressure flow. Consequently, the thermal transpiration pump can be improved by the implementation of several suggestions to archive a more efficient gas flow.

Item Type: Final Year Project (Project Report)
Uncontrolled Keywords: Cold chamber parameter, Gas flow, Thermal transpiration pump, Temperature
Subjects: T Technology > TS Manufactures
Divisions: Library > Final Year Project > FTKMP
Depositing User: Sabariah Ismail
Date Deposited: 27 Feb 2024 03:30
Last Modified: 27 Feb 2024 03:30
URI: http://digitalcollection.utem.edu.my/id/eprint/30814

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year