Abstract

In this tropical climate state, particularly in Malaysia, it is classified by elevated temperature and this phenomenon resists human heat comfort in building compared to other places with massive job operations, small private office space usually has a low cooling load. High energy usage and initiating price for compressor-based units used in tiny rooms is a massive waste instead of using little mobile air conditioning. Using the Peltier impact module, the small private air-conditioning scheme is exposed to regulate the amount of convenience by reducing sensible and latent heat inside the room. Peltier module or thermoelectric module is a thermoelectric semiconductor that provides cooling and hot plate after electric is supply to the plate, whereas Peltier has different performance and this project proves that with a series circuit, performance of Peltier higher compared to the previous researcher. This project’s ability to reduce the power consumption, cost and provide thermal comfort zone in a dedicated area. The benefit of this project can cut the cost by reducing power consumption and also green technology devices because of not using a refrigerant that can harm the world. By redesigning this product and using Evapolar as heat waste management, the performance of the product needs to be calculated. Process preparation of this product is different compared to a previous product which it’s smaller, less heavy, and portable to bring anywhere. This product focusing on the office room, which gives comfort to occupants. This product uses air to remove the heat waste and data shows Evapolar is efficient enough in removing heat. Performance for this product without a controller of temperature shows that it can achieve thermal comfort level.

Item Type: Final Year Project (Project Report)
Uncontrolled Keywords: Air Conditioning, Energy Conservation, Energy Consumption, Waste Heat
Subjects: T Technology > T Technology (General)
T Technology > TH Building construction
Divisions: Library > Final Year Project > FTKMP
Depositing User: Norfaradilla Idayu Ab. Ghafar
Date Deposited: 07 Apr 2021 08:52
Last Modified: 07 Apr 2021 08:52
URI: http://digitalcollection.utem.edu.my/id/eprint/25114

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year