Ng, Che Han (2019) Battery Thermal Management By CFD. Project Report. UTeM, Melaka, Malaysia. (Submitted)
![]() |
Text (24 Pages)
Battery Thermal Management By CFD.pdf - Submitted Version Download (562kB) |
Abstract
The aim of this study is to compare the cooling effect of a liquid flow channel with different types of inner edge on the battery surface. The numerical study was performed using ANSYS FLUENT. A geometric model of cuboid-shaped battery with two tabs was created. Cooling plate with the fluid channel was attached on both sides of the battery cell. The flow channel with a sharp edge was compared with the one with 5mm and 10mm fillet corner. The simulation of the battery was carried out by using Multi-Scale Multi-Domain (MSMD) method, which was provided in ANSYS FLUENT. All three cases were simulated under the same operational condition. The results showed that the fluid channel with fillet corner gives a neglectable small temperature different on battery cell. This may due to the velocity is not high enough to have a presence of separation region in sharp edge case or fillet corner and mesh size generated may also not small enough to capture the detailed result.
Item Type: | Final Year Project (Project Report) |
---|---|
Uncontrolled Keywords: | Lithium ion batteries, Heat, Transmission, Battery charges |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Divisions: | Library > Final Year Project > FKM |
Depositing User: | Sabariah Ismail |
Date Deposited: | 18 Sep 2020 04:13 |
Last Modified: | 18 Sep 2020 04:13 |
URI: | http://digitalcollection.utem.edu.my/id/eprint/24572 |
Actions (login required)
![]() |
View Item |