Performance Analysis Of 1HP Split Type Room Air Conditioner Using Refrigerant R410A And R32

Tan, Ren Jie (2017) Performance Analysis Of 1HP Split Type Room Air Conditioner Using Refrigerant R410A And R32. Project Report. UTeM, Melaka, Malaysia. (Submitted)

[img] Text (24 Pages)
Performance Analysis Of 1HP Split Type Room Air Conditioner Using Refrigerant R410A And R32.pdf - Submitted Version

Download (594kB)

Abstract

Air conditioning is a widely used technology that conditions an indoor air to a comfortable temperature or a specific temperature adequate to human comfort. The global demand of split type room air conditioning system boosts every year and caused the Earth’s climate worst as a result of global warming due to the emission of fluorine into the atmosphere from the refrigerant that contained in the air conditioning equipment. For split type room air conditioner, new refrigerant (R32) that have lower global warming potential (GWP) have been developed as compensate and to substitute the currently in used refrigerant (R410A) that has higher GWP which deals more damage to the atmosphere. The objectives of this research are to collate operating conditions (energy consumption, temperatures, pressures) and coefficient of performance (COP) of both refrigerant R410A and R32 that operated in both 1hp (horsepower) split type room air conditioners. The experiment research involved two 1hp split type room air conditioners which using different refrigerant (R410A and R32) under the same condition. Validation will be made based on the data collected during the experiment. Instruments such as Digital Thermometer, Manifold Gauges and Power Quality and Energy Analyzer will be used in aiding the data collecting session. The data collected will undergo further analysis by manually using Mollier Chart and software (TechniSolve) in determining the COP of the system. Conclusively, this research is mainly contributes for helping to determine the performance of refrigerant R32 in substituting the currently R410A using in split type room air conditioner.

Item Type: Final Year Project (Project Report)
Uncontrolled Keywords: Buildings - Energy conservation, Dwellings - Energy conservation, Refrigeration and refrigerating machinery, Air conditioning - Energy consumption
Subjects: T Technology > T Technology (General)
T Technology > TL Motor vehicles. Aeronautics. Astronautics
Divisions: Library > Final Year Project > FTK
Depositing User: Mohd Hannif Jamaludin
Date Deposited: 21 Nov 2018 04:09
Last Modified: 21 Nov 2018 04:09
URI: http://digitalcollection.utem.edu.my/id/eprint/21963