Browse By Repository:

 
 
 
   

Retrofitting project for improved chiller system performance in a hotel, Kuala Lumpur, Malaysia

Razak, Muhammad Aiman (2024) Retrofitting project for improved chiller system performance in a hotel, Kuala Lumpur, Malaysia. Project Report. Universiti Teknikal Malaysia Melaka, Melaka, Malaysia. (Submitted)

[img] Text (24 Pages)
Retrofitting project for improved chiller system performance in a hotel, Kuala Lumpur, Malaysia.pdf - Submitted Version

Download (397kB)
[img] Text (Full text)
Retrofitting project for improved chiller system performance in a hotel, Kuala Lumpur, Malaysia.pdf - Submitted Version
Restricted to Registered users only

Download (1MB)

Abstract

This thesis addresses the pressing issue of energy inefficiency in commercial buildings, with a specific focus on the hotel industry, by investigating the impact of aging chiller systems. In response to the heightened environmental awareness, this research aims to contribute to sustainable practices through a comprehensive retrofitting project at the Sheraton Imperial Hotel Kuala Lumpur. The objectives include analyzing current chiller system inefficiencies, measuring improvements post-retrofitting, and evaluating economic feasibility. The methodology involves a preliminary energy audit, chiller selection considerations, and financial assessments. The retrofitting initiative, involving the replacement of the aging 19XR chiller with a Carrier 23XRV water-cooled chiller and Variable Frequency Drive (VFD) technology, demonstrates a remarkable 54% improvement in chiller plant efficiency. Financial analyses indicate a profitable venture with an expected annual electricity bill decrease, a payback period of 4.064 years, and a substantial return on investment (ROI) of 25%. The success of this retrofitting project not only establishes the Sheraton Imperial Hotel as a leader in operational excellence and environmental responsibility but also provides valuable insights for similar initiatives in the hospitality sector. Continuous monitoring and future research efforts are recommended to ensure long-term performance improvements and to inspire the adoption of sustainable practices throughout the industry.

Item Type: Final Year Project (Project Report)
Uncontrolled Keywords: Retrofit, Energy efficiency, Chiller system enhancement, Sustainable energy, Variable frequency drive
Subjects: T Technology > TH Building construction
Divisions: Library > Final Year Project > FTKE
Depositing User: Sabariah Ismail
Date Deposited: 31 Jul 2024 04:55
Last Modified: 31 Jul 2024 04:55
URI: http://digitalcollection.utem.edu.my/id/eprint/32911

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year